Boulder Creek above WW Plant |
For February, 2005 the WQI rating at Boulder Creek above WW Plant (BC-aWWTP) was Good (B) due to a WQI value of 79.85.
The chart below details the WQI calulations at this site. See the detailed explanation of the WQI method for more information.
Parameter | Unit | Parameter Value | Q-value | Weight Factor | Total |
---|---|---|---|---|---|
DO% | % sat | 125.00 | 87.80 | 0.17 | 14.93 |
Fecal Coliform | #/100 mL | Data Unavailable | |||
pH | pH | 8.90 | 53.11 | 0.11 | 5.84 |
Total Phosphate | mg PO4/L | 0.02 | 98.23 | 0.10 | 9.82 |
Nitrates | mg NO3/L | Data Unavailable | |||
Turbidity | NTU | 2.20 | 92.13 | 0.08 | 7.37 |
Total Solids | mg/l | 265.00 | 62.26 | 0.07 | 4.36 |
Totals (factors, total) | 0.53 | 42.32 | |||
Adjusted WQI | 79.85 |
The WQI is computed by converting measured Water Quality Parameters to "Q-Values" using charts developed by the National Sanitation Foundation (NSF) water quality scientists. The Q-Values are then multiplied by a weighting factor based on the importance of that water quality parameter. These values are totaled and then divided by the sum of the weight factors.