Boulder Creek above WW Plant |
For February, 2002 the WQI rating at Boulder Creek above WW Plant (BC-aWWTP) was Good (B) due to a WQI value of 82.73.
The chart below details the WQI calulations at this site. See the detailed explanation of the WQI method for more information.
Parameter | Unit | Parameter Value | Q-value | Weight Factor | Total |
---|---|---|---|---|---|
DO% | % sat | 78.60 | 82.77 | 0.17 | 14.07 |
Fecal Coliform | #/100 mL | Data Unavailable | |||
pH | pH | 7.86 | 90.16 | 0.11 | 9.92 |
Total Phosphate | mg PO4/L | Data Unavailable | |||
Nitrates | mg NO3/L | Data Unavailable | |||
Turbidity | NTU | Data Unavailable | |||
Total Solids | mg/l | 0.00 | 100.00 | 0.07 | 7.00 |
Parameter | Unit | Parameter Value | Q-value | Weight Factor | Total |
---|---|---|---|---|---|
DO% | % sat | 79.90 | 84.23 | 0.17 | 14.32 |
Fecal Coliform | #/100 mL | 20.00 | 61.54 | 0.16 | 9.85 |
pH | pH | 7.87 | 90.16 | 0.11 | 9.92 |
Total Phosphate | mg PO4/L | 0.02 | 98.23 | 0.10 | 9.82 |
Nitrates | mg NO3/L | 0.10 | 97.90 | 0.10 | 9.79 |
Turbidity | NTU | 2.31 | 91.31 | 0.08 | 7.30 |
Total Solids | mg/l | 264.00 | 62.26 | 0.07 | 4.36 |
Totals (factors, total) | 0.79 | 65.36 | |||
Adjusted WQI | 82.73 |
The WQI is computed by converting measured Water Quality Parameters to "Q-Values" using charts developed by the National Sanitation Foundation (NSF) water quality scientists. The Q-Values are then multiplied by a weighting factor based on the importance of that water quality parameter. These values are totaled and then divided by the sum of the weight factors.