Boulder Creek above WW Plant |
For March, 2002 the WQI rating at Boulder Creek above WW Plant (BC-aWWTP) was Good (B) due to a WQI value of 85.29.
The chart below details the WQI calulations at this site. See the detailed explanation of the WQI method for more information.
Parameter | Unit | Parameter Value | Q-value | Weight Factor | Total |
---|---|---|---|---|---|
DO% | % sat | 0.00 | 99.00 | 0.17 | 16.83 |
Fecal Coliform | #/100 mL | 20.00 | 61.54 | 0.16 | 9.85 |
pH | pH | 7.90 | 89.67 | 0.11 | 9.86 |
Total Phosphate | mg PO4/L | 0.02 | 98.23 | 0.10 | 9.82 |
Nitrates | mg NO3/L | 0.10 | 97.90 | 0.10 | 9.79 |
Turbidity | NTU | 1.41 | 93.93 | 0.08 | 7.51 |
Total Solids | mg/l | 335.00 | 53.06 | 0.07 | 3.71 |
Totals (factors, total) | 0.79 | 67.38 | |||
Adjusted WQI | 85.29 |
The WQI is computed by converting measured Water Quality Parameters to "Q-Values" using charts developed by the National Sanitation Foundation (NSF) water quality scientists. The Q-Values are then multiplied by a weighting factor based on the importance of that water quality parameter. These values are totaled and then divided by the sum of the weight factors.